LDO LCP300-24D5 300W 24V and 5V Compact Power Supply (PSU)

LDO SystemsSKU: LDOLCP300

Preis:
Sonderpreis€59,95

Beschreibung

The LCP300-24D5 is a compact, fully enclosed 300W dual-output power supply for 3D printing applications. Featuring power factory correction and Gallium Nitride technology, the LCP300-24D5 provides 24V and 5V outputs with an efficiency of over 90%.

Features

  • Dual output: 24VDC (x3) and 5VDC (x1)
  • Highly compact (120×95×35mm) and fully enclosed
  • GaN technology with PFC and efficiency of up to 91%
  • Overload, overvoltage, and temperature protection
  • Wide AC input: 100-240VAC
  • Dual AC input terminals, supporting AC series connection

Model Breakdown

Electrical Specifications

Model LCP300-24D5
Output Output Voltage 5V 24V
Max Current 5A 11.45A
Max Power 25W 275W
Ripple & Noise (Max)2 150mVp-p 360mVp-p
Line Regulation ±1% ±1%
Load Regulation ±5% ±2%
Start-up / Rise Time3 3000ms/115VAC,≤100ms/220VAC
Hold-up Time4 ≥8.3ms at full load
Input Voltage Range 100 - 240VAC
Frequency Range 50-60Hz
Efficiency ≥91%
AC Current 3.5A/115VAC  2A/230VAC
Inrush Current ≤50A/220VAC cold start 
Leakage Current ≤0.75mA, 240VAC/50Hz
L/N Terminal Current5 12A Max
Protection Features Overload Protection ≥110% of rated output power
5.2-6A (5V), 13-17A (24V), output voltage shuts off; recovers automatically after fault removal
Overvoltage Protection ≥135% of rated output voltage
Output voltage shuts off; recovers automatically after fault removal
Temperature Protection When enclosure surface temperature exceeds 110°C
Output voltage stops until temperature drops below 80°C
Environmental Conditions Operating Temperature -20~40℃
Operating Humidity 10~90%
Storage Temperature & Humidity -30~85℃/ 5~90%
Vibration 10-500Hz, 2G, 10 minutes/cycle, 60 minutes in each X, Y, and Z direction
Safety & Compliance Safety Standards  
High Voltage Resistance 2.5KVAC
Insulation Resistance ≥100MΩ
EMC Immunity Compliant with EN/IEC: EN55032
Harmonic Standards Compliant with IEC61000-3-2
Others Dimensions 120.0mm (L) * 95.0 mm (W) * 35.0 mm (H)
Packaging  132x105x39mm
MTBF 50000h (25℃)
Notes
  1. Unless otherwise specified, all specifications are measured under 230VAC input, rated load, and 25°C ambient temperature.
  2. Ripple and noise measurement: Measured at the end of the output cable, with a 0.1μF ceramic capacitor and a 47μF electrolytic capacitor.
  3. Start-up time: The time from when power is applied to the input until the output voltage rises to 90% of its rated value. Rise time: The time required for the power supply to reach its rated output value from a no-power state.
  4. Hold-up time: The duration from when the AC input is cut off to when the output drops below 5% of the standard value.
  5. L/N terminal current: Refers to AC voltage interface, where a single input is used to distribute one output. The maximum current the AC voltage interface can withstand is 12A.

For more information please see LDO Docs.

You may also like